ELS Coin-meter with display, Generation 6 –series, Classic
 
Installation:
The 6-pole connector from coin-meter should be connected to the Timer terminal X21 (wires toward rotary switch).

It should be "plug and play"
When you apply voltage it will take a few seconds and the display will lit up and show "remaining coins to start".
It is initiated with a preset value that is set in the service program (default from factory 5 coins).
 
Normal operation:
When fitting coins, the display will count down to "00" and machine will start.
When started the coin-meter will indicate "- -" to show that machine is in operation.
When wash program is ended, coin-meter will return to preset value ex "05" coins and be ready for a new start.
 
Start when door opened:
When inserting coins, the display will count down to "00" and attempt to start machine.
After 3 seconds coin-meter indicates "od" for open door.
When door is closed machine will start normally as described above.
 
Some additional information:
Coins fitted when in "od" or "- -" mode, will be counted in total counter but not remembered to next wash.
Coin-meter will remember coins that is fitted when/if power fails.
 
Service mode:
The encoder switch is used to enter and navigate in service mode only.
The encoder/all configuration is accessible by removing the coin-box, either by using your hand or by an
extension such as a screwdriver or similar. (see pictures below).
By pressing the encoder during >3 sec, you will enter service mode - "SE".

By turning clockwise , you will have 5 menu's available.

P1 - Number of coins
P6 - Total counter for coins MS (Most significant i.e. 99xxxx)
P7 - Total counter for coins (Middle significant i.e. xx99xx)
P8 - Total counter for coins LS (Least significant i.e. xxxx99)
ES- Exit service

P1 - Number of coins.
Preset value for price, i.e. number of coins to start a wash.
Select P1. Press encounter once.
Now actual setting will turn up (value between 01-99).
Turn encoder (clockwise or anticlockwise) to select the preferred price.
Press encounter once to set price.
P6 - Total counter for coins MS (Most significant i.e. 99xxxx)
Select P6. Press encounter once.
Most significant value will now be displayed.
Press encounter once to Exit.
P7 - Total counter for coins (Middle significant i.e. xx99xx)
Select P7. Press encounter once.
Least significant value will now be displayed.
Press encounter once to Exit.
P8 - Total counter for coins LS (Least significant i.e. xxxx99)
Select P8. Press encounter once.
Least significant value will now be displayed.
Press encounter once to Exit.
 
ES- Exit service
Select ES. Press encounter once.
You are now back in Normal operation mode again.
Total counter will count to 999999 and then start over on 000000 again.
 